Short answer
Confirm the voltage class first: 12 kV distribution takes the KYN28A-12 (12 kV, 630 A, 50 Hz, customised non-standard OEM); 40.5 kV takes the KYN61-40.5; compact outdoor switching takes the SF6 ring main unit; a complete substation takes the HZB-12 box-type substation or a prefabricated cabin.
Introduction
Switchgear is the equipment that controls, protects, and isolates power in a distribution network — the point where a wrong choice shows up as a failed inspection, a cabinet that does not fit the room, or a project delayed while a replacement is ordered. This guide explains how to choose between the main types Huailite Power supplies, what to check first, and what information to send when requesting a quote.
Huailite Power supplies switchgear and substations for distribution projects in the Middle East, Africa, and South America, with selection support, spare parts, after-sales service, and installation guidance on every order. Browse the full range on the Switchgear & Substations landing page.
1. Metal-clad switchgear: KYN28A-12 and KYN61-40.5
Metal-clad, withdrawable switchgear is the standard choice for indoor medium-voltage distribution — substations, industrial plants, and commercial buildings where the breaker must be racked out for maintenance without shutting down the whole board.
The KYN28A-12 Metal-Clad Switchgear is the 12 kV workhorse of this range. Its base configuration is 12 kV, 630 A, 50 Hz, built from cold-rolled steel plate in a withdrawable metal-clad design. Important for buyers: the KYN28A-12 is a customised, non-standard OEM product. Dimensions, appearance, layout, plate thickness, and colour can all be built to order, so the right way to specify it is to send your single-line diagram, room dimensions, and breaker and protection requirements — not to look for one fixed catalogue size.
The KYN61-40.5 covers the higher-voltage end of the same family (the 40.5 in its model name is its voltage class). If your project is 12 kV distribution, start with the KYN28A-12; if it is a 40.5 kV system, the KYN61-40.5 is the matching metal-clad option. Confirm the voltage class first — it is the single decision that narrows the whole selection.
2. Ring main units: compact switching for secondary distribution
A ring main unit (RMU) is the compact answer where space is tight and the job is switching and protecting a loop or spur of the network rather than a full substation board: residential districts, commercial developments, and outdoor secondary substations.
The SF6 Ring Main Unit is Huailite Power’s RMU offering. Choose an RMU when the load is modest, the installation is outdoors or in a small kiosk, and you need a sealed, low-maintenance switching point. Choose metal-clad switchgear instead when you need withdrawable breakers, extensive protection and metering, or many outgoing feeders in one lineup.
3. Box-type substations and prefabricated cabins: the whole substation, delivered
When a project needs a complete, ready-to-energise substation rather than individual panels, the choice is between a box-type substation and a prefabricated cabin.
The HZB-12 Box-Type Substation packages transformer, switchgear, and low-voltage distribution into one outdoor enclosure — the practical option for sites that need power quickly with minimal civil works: construction sites, industrial parks, and rural electrification. A prefabricated cabin serves the same idea at a larger scale, housing a full switchgear lineup indoors in a transportable building. Both are built to the project’s layout, so send the site plan and load list with your enquiry.
4. Low-voltage distribution: MNS, GGD, and JP cabinets
Below the medium-voltage board sits the low-voltage distribution that actually feeds the loads. The range covers three roles: the MNS low-voltage withdrawable switchgear for larger low-voltage boards where individual drawers must be isolated for maintenance; the GGD fixed distribution cabinet for straightforward low-voltage distribution; and the JP distribution cabinet for outdoor low-voltage distribution at the network edge. PLC automation control cabinets are available alongside these for projects that need control and automation in the same order.
5. How to specify a switchgear order — a checklist
Send these with your enquiry and the quote will be accurate the first time:
- Voltage class and system frequency — 12 kV, 40.5 kV, or low voltage; 50 Hz or 60 Hz.
- Rated current and short-circuit level — the load the board must carry and the fault level it must withstand.
- Indoor or outdoor, and the space available — room dimensions for metal-clad boards, or site conditions for box-type substations and RMUs.
- Number of incoming and outgoing feeders, and what protection and metering each needs.
- Customisation — for the KYN28A-12, the dimensions, layout, plate thickness, and colour you need; for cabins and substations, the site plan.
- Quantity, destination port, and project timeline — pricing is quoted per customer and project, so these decide the quote.
If any of these is not yet fixed, say so in the enquiry — Huailite Power’s selection support can work from a single-line diagram and a load list.
| Model | Type | Voltage / rating | Notes |
|---|---|---|---|
| KYN28A-12 | Metal-clad switchgear | 12 kV, 630 A, 50 Hz | Customised non-standard OEM; withdrawable; cold-rolled steel plate |
| KYN61-40.5 | Metal-clad switchgear | 40.5 kV | |
| SF6 ring main unit | Ring main unit | Medium-voltage distribution | Compact, sealed, for outdoor or small kiosk use |
| HZB-12 | Box-type substation | Outdoor power distribution | Transformer, switchgear, and low-voltage distribution in one enclosure |
| Prefabricated cabin | Prefabricated cabin substation | Full switchgear lineup indoors, in a transportable building | |
| MNS | Low-voltage withdrawable switchgear | Low-voltage | Individual drawers can be isolated for maintenance |
| GGD | Fixed distribution cabinet | Low-voltage | Straightforward low-voltage distribution |
| JP | Distribution cabinet | Low-voltage, outdoor | Outdoor low-voltage distribution at the network edge |
| PLC control cabinet | Automation control cabinet | Equipment automation and process automation control |
FAQ
How do I request a quote for switchgear? Send the model, quantity, and project details to sales@staging.huailitepower.com or use the contact form. Pricing is quoted per customer and project and is not listed online.
Is the KYN28A-12 a standard off-the-shelf cabinet? No. It is a customised, non-standard OEM product: 12 kV, 630 A, 50 Hz, cold-rolled steel plate, withdrawable metal-clad construction, with dimensions, appearance, layout, thickness, and colour built to order.
Do you show prices for switchgear online? No. All products are supplied to business customers and quoted per project. Contact sales for a quote.
Request a quote
Tell us the voltage class, the number of feeders, and whether the installation is indoor or outdoor, and we will quote the matching switchgear — KYN28A-12, KYN61-40.5, ring main unit, box-type substation, or distribution cabinet — for your project. Request a Quote · sales@staging.huailitepower.com · +86 13049969968 · WhatsApp: +86 13049969968.