Line Hardware

Fittings, insulators, and accessories for overhead transmission and distribution lines.

49 products · No public prices — request a quote.

Huailite Power supplies overhead line hardware and fittings for utilities and EPC contractors in the Middle East, Africa, and South America: tension strings, line fittings, iron attachments, and power accessories. Browse by category below, or send your line voltage and fitting list for a quote.

How to choose line hardware and fittings

Line hardware is chosen by three numbers: the conductor diameter, the line voltage, and the breaking load. Start with the suspension clamp, which holds the conductor at the tower. Our XG series covers conductors from 13.2 mm to 54.0 mm and breaking loads from 40 kN to 80 kN: the XG-4022 is rated 40 kN for conductors of 13.2–22.0 mm, the XG-6046 is rated 60 kN for 36.8–46.0 mm, and the XG-8054 is rated 80 kN for 43.2–54.0 mm. Pick the clamp whose conductor range contains your conductor and whose breaking load is above the line’s maximum tension.

Next, size the rest of the string to the same load. Yoke plates (L series) cover 70–420 kN, Z-type adjusting plates cover 70–400 kN, socket eyes (W and WS series) cover 70–320 kN, parallel plates (PS series) cover 70–300 kN, and shackles (U and UL series) cover 70–200 kN. Every fitting in a string must be rated at or above the design tension — the weakest link decides the string, so check the smallest rating in the set, not the largest. Wedge clamps (NX-1 to NX-4) are rated 45, 88, 143, and 164 kN, and stay rods are sized by diameter: Φ16 mm at 74 kN, Φ20 mm at 117 kN, and Φ24 mm at 169 kN. NXL wedge-type strain clamps are matched to the conductor: they cover conductors from 35 mm² to 400 mm², with grip strength from 3.4 kN to 39.8 kN and breaking load from 7.5 kN to 61 kN.

Insulators follow the same rule. Suspension porcelain insulators (U40B to U300B) are rated by electromechanical failing load from 40 kN to 300 kN — U40B at 40 kN, U70B at 70 kN, U100B at 100 kN, U120B at 120 kN, U160B at 160 kN, U210B at 210 kN, U240B at 240 kN, and U300B at 300 kN — so choose the rating above the line’s maximum tension, with margin. Vibration dampers (FR-1 to FR-4) are matched to conductor diameter: FR-1 for 7–12 mm, FR-2 for 11–22 mm, FR-3 for 18–28 mm, and FR-4 for 23–36 mm.

For OPGW lines, the fittings are matched to the cable diameter. The OPGW down-lead clamp fits cables of 9.0–17.0 mm, the OPGW tension string fits cables of 9.0–11.4 mm, and the OPGW suspension string is supplied as a complete set — JDX70-2000 hanging plate, JB-1 parallel groove clamp, UB-7 ring, PD-7 connecting plate, TK-7 suspension point, XJ rubber part, and OXY1000 70-W and 70-N clamp shells — so the whole string is ordered as one item. Send the line voltage, conductor size, and design tension, and we will match the clamp, plates, shackles, insulator, and damper as one string.

ModelSuitable conductor diameterBreaking loadWeight
XG-402213.2–22.0 mm40 kN1.75 kg
XG-402819.6–28.0 mm40 kN2.56 kg
XG-403427.4–34.0 mm40 kN3.35 kg
XG-602819.6–28.0 mm60 kN2.56 kg
XG-603427.4–34.0 mm60 kN3.35 kg
XG-604032.0–40.0 mm60 kN3.57 kg
XG-604636.8–46.0 mm60 kN3.95 kg
XG-803427.4–34.0 mm80 kN3.35 kg
XG-804032.0–40.0 mm80 kN3.95 kg
XG-804636.8–46.0 mm80 kN3.95 kg
XG-805443.2–54.0 mm80 kN4.8 kg

Frequently asked questions

Why do some fittings show two model numbers, for example WS-16 / WS-1695?
Both numbers are correct and identify the same fitting — they are not misprints. The same applies to WS-30 / WS-32110. Quote either number and we will supply the same fitting.

How do I choose a suspension clamp?
Match the conductor diameter and the breaking load together. The XG-4022 is rated 40 kN for conductors of 13.2–22.0 mm, the XG-6046 is rated 60 kN for 36.8–46.0 mm, and the XG-8054 is rated 80 kN for 43.2–54.0 mm. Pick the clamp whose conductor range contains your conductor and whose breaking load is above the line’s maximum tension.

What breaking loads do the fittings cover?
Yoke plates (L series) cover 70–420 kN, Z-type adjusting plates 70–400 kN, socket eyes (W / WS series) 70–320 kN, parallel plates (PS series) 70–300 kN, shackles (U / UL series) 70–200 kN, and wedge clamps (NX-1 to NX-4) 45–164 kN. Every fitting in a string must be rated at or above the design tension.

Which insulator do I need for my line?
Suspension porcelain insulators (U40B to U300B) are rated by electromechanical failing load from 40 kN to 300 kN — U40B at 40 kN, U70B at 70 kN, U100B at 100 kN, U120B at 120 kN, U160B at 160 kN, U210B at 210 kN, U240B at 240 kN, and U300B at 300 kN. Choose the rating above the line’s maximum tension, with margin.

What OPGW cable diameters do the fittings cover?
The OPGW down-lead clamp fits cables of 9.0–17.0 mm and the OPGW tension string fits cables of 9.0–11.4 mm. The OPGW suspension string is supplied as a complete set — JDX70-2000 hanging plate, JB-1 parallel groove clamp, UB-7 ring, PD-7 connecting plate, TK-7 suspension point, XJ rubber part, and OXY1000 70-W and 70-N clamp shells.

Categories

Browse by category, then request a quote for your project.

Line Hardware & Fittings

Line Hardware & Fittings

Tension strings, fittings, and iron attachments.

47 products

View category →

Power Accessories

Power Accessories

Surge protection and copper busbar sets.

2 products

View category →