A 10 kV or 35 kV overhead line is held together by hundreds of small parts, and the list that describes them can look like alphabet soup: W, WS, Z, PS, L, JY, NY, NXL, XP, U, UL, Q, XG, DB, FR, NUT, NX, BDSS. Every letter stands for a family with its own way of writing model numbers. This guide explains how to read the overhead line hardware list — 296 products across seven groups — so you quote the right part the first time.
The catalogue sections cover 10 kV and 35 kV lines, within a product range designed for 10 kV to 220 kV transmission-line applications. Most iron fittings are Q235 steel, hot-dip galvanised for corrosion protection. Every table is transcribed exactly as printed; blank cells stay blank.
Short answer
A 10 kV or 35 kV line uses 296 fittings in seven groups — 35 kV fittings (134), 10 kV tension strings (72), 10 kV iron attachments (39), stay-wire fittings (30), 35 kV iron attachments (15), OPGW fittings (5), and one transformer platform set. Quote the model and the size together: NXL-1 for 35 mm² is a different product from NXL-1 for 50 mm², and W-7A and W-0770 are the same fitting under two numbers.
The Seven Groups
| Group | المنتجات | What it covers |
| 35kV Fittings | 134 | Socket eyes, yoke plates, clamps, insulators, and links for 35 kV lines |
| 10kV Tension Strings | 72 | Tension string hardware for 10 kV lines |
| 10kV Iron Attachments | 39 | Crossarms, hoops, braces, and plates |
| Stay-Wire Fittings | 30 | Stay rods, pull rings, and stay hardware |
| 35kV Iron Attachments | 15 | Iron attachments for 35 kV lines |
| OPGW Fittings | 5 | Fittings for optical ground wire |
| Transformer Platforms | 1 | Pole-mounted transformer platform set |
Walk the Tension String, Link by Link
A tension string is a chain of fittings: clamp, insulator, and link plates, in order.
- Tension clamps NXL-1 to NXL-5 (10 models) — wedge tension clamps sized by conductor cross-section. NXL-1 for 35 mm² is a different product from NXL-1 for 50 mm². Always quote the conductor size as well as the model.
- Disc suspension porcelain insulators XP-40 to XP-300 (26 models) — cap-and-pin insulators in classes from U40C/U40B up to U300B, with leakage distance printed per model (for example XP-70 U70BL, 295 mm). Quote the class as well as the type: XP-70 alone is not a complete specification.
- Ball eyes Q-7 and QP-7/10/12 (4 models) — the ball end of the ball-and-socket connection.
- Socket eyes W-7A to W-32110 (11 models) and WS-7 to WS-32110 (14 models) — the socket end that mates with the ball eye.
- Right-angle plates Z-7 to Z-40 (10 models) — for changing the direction of the string.
Every link in the chain has a specified failure load (kN) printed in the catalogue. Check that each link meets your design load before you order — the weakest link decides the string.
The Dual Numbering Trap
The W, WS, Z, and PS tables list each product under two numbering systems: a general design number and a catalogue model number. This is where most ordering mistakes happen.
- Same product, two numbers. Where dimensions and weight are identical, it is one product with two numbers, and we list it once with both numbers shown — for example W-7A = W-0770, WS-7 = WS-0770, and WS-10 = WS-1085.
- Different product, similar numbers. Where the weight differs, we list them as separate products. Do not assume two similar numbers are the same part — check the weight column.
- Two families that look identical. U-shackles U-7 to U-21 (5 models) and UL-shackles UL-7 to UL-21 (5 models) print identical values, but the drawings differ slightly, so they are listed as separate products. Quote the letter as well as the number.
The same rule applies across the list: the model number alone is rarely enough. Yoke plates L run from L-1040 to L-21/32-130/600 (49 models, the largest single family), with hole diameters, plate thickness, specified failure load, and weight printed per model. Splicing sleeves JY run from JY-120/20 to JY-800/100 (32 models) and are sized by conductor. Hydraulic tension clamps NY run from NY-150/20 to NY-400/95 (21 models).
Reading the Other Groups
- 10kV iron attachments: crossarm HD(P)-16/7508, supplied with fabrication drawings; reinforced hoops LB-200 to LB-390 (20 models) in pole diameters from 200 mm to 390 mm, each with a stiffening plate and M20×100 bolts, 6.8 grade, double nut and double washer; double-top double-hoop BDSS-190 — one product in five size variants (D 200, 240, 280, 360, 440 mm); braces ZX-800 to ZX-1600 (17 models); and the transformer platform set, supplied as a set with its bill of materials.
- 35kV fittings: adjuster plates DB (12 models, DB-7 to DB-32G), parallel plates PS (7 models, PS-7 to PS-10100), suspension clamps XG (11 models, XG-4022 to XG-8054), vibration dampers FR-1 to FR-4 (4 models), counterweight disc ZC-15Y and counterweight seat FZJ-15, and DG18 iron attachments (12 models), HB180-3, HJM-3, and HZM-2 — supplied with bills of materials rather than model tables.
- Stay-wire fittings: UT clamps NUT-1 to NUT-4 (4 models), stay rods Φ16/20/24 (11 models) in lengths from 2000 mm to 4200 mm, with breaking tensile force of 74 kN (Φ16), 117 kN (Φ20), and 169 kN (Φ24) as printed, stay disc pull ring LPU-28 with a bill of materials, and wedge clamps NX-1 to NX-4 (4 models).
- OPGW fittings: five products for optical ground wire — OPGW tension string, OPGW suspension string, tower joint box, tower spare-cable rack, and down-lead clamp. The suspension string is supplied with a bill of materials.
How to Build Your BOM From This List
- Start from the line design — voltage (10 kV or 35 kV), conductor type and size, and the string type (tension or suspension).
- Walk the string — clamp, insulator, ball eye, socket eye, yoke plate, and right-angle plate, in order, checking the specified failure load of each link.
- Add the pole hardware — crossarm, reinforced hoop to suit the pole diameter (LB-200 to LB-390), braces, and stay-wire fittings.
- Add the consumables the tables imply — splicing sleeves (JY) by conductor size, vibration dampers (FR) by span, and counterweights where specified.
- Quote model and size together — NXL-1 for 35 mm² is a different product from NXL-1 for 50 mm², and XP-70 U70BL is a different product from XP-70 U70BS. Sending the model number alone risks the wrong part.
See the full range on the Line Hardware & Fittings page.
الأسئلة الشائعة
Why do some models have two numbers, for example W-7A and W-0770?
The catalogue lists products under both a general design number and a catalogue model number. Where dimensions and weight are identical, it is one product with two numbers, listed once with both shown. Where the weight differs, we list them separately.
What voltage are these fittings for?
The catalogue sections cover 10 kV and 35 kV lines, within a product range designed for 10 kV to 220 kV applications. Check the specified failure load (kN) on each product page against your line design.
Are the iron fittings galvanised?
Most iron fittings in this catalogue are Q235 steel with hot-dip galvanising for corrosion protection, as stated in the catalogue notes. Check the product page for the specific model.
Why is the conductor size needed with an NXL clamp model?
NXL clamps are sized by conductor cross-section. NXL-1 for 35 mm² and NXL-1 for 50 mm² are different products, so the model number alone is not a complete order.
Do you publish prices for line hardware?
No. All products are B2B and priced per project. Request a quote with the model, size, and quantity, and we will quote for your project.
—
*Browse the full range on the Line Hardware & Fittings page or shop all products.*